Knowledge bank

Choosing a pump for corrosive media: how to select the right pump

The most suitable chemical pump is determined primarily by the properties, concentration and temperature of the medium, but also by flow rate, pressure, particles, gas formation and how the pump is to be operated.

When it comes to pumps for corrosive media, it is particularly important that the pump type and the materials used in the parts in contact with the fluid are selected on the basis of the specific process. In this article, we outline the factors that determine pump selection and provide guidance for three common media: hydrochloric acid, sodium hypochlorite and caustic soda.

What determines the choice of pump

When pumping aggressive and corrosive fluids, several factors need to be taken into account. A pump that performs well in one application may be unsuitable in another, even if the fluids belong to the same chemical group.

Let’s go through four groups of criteria:

 

Medium, concentration and temperature

The first step is to identify exactly which fluid is to be pumped. The name of the chemical is not always sufficient. The concentration and temperature can affect the chemical resistance of the material and, consequently, which pump is suitable.

When pumping corrosive liquids, the material of all parts that come into contact with the liquid must be checked. This applies not only to the pump casing but also, for example, to seals, diaphragms, impellers, valves and other components that come into contact with the fluid.

That is why the choice of material always follows the choice of pump. A particular type of pump may be available in several material variants, and the correct combination depends on the specific process.

Please feel free to read more about our choice of materials materials guide.

Particles, viscosity and gas formation

Particles in the fluid can significantly alter the operating conditions. They can cause wear and affect components such as impellers, valves and seals. Where fluids contain particles, a different type of pump may therefore be more suitable than a traditional centrifugal pump.

Viscosity also needs to be taken into account. A high-viscosity fluid behaves differently within the pump system than a low-viscosity fluid and may require a different pumping solution.

Gas formation is another factor that may affect the recommendation. If the fluid releases gas, the pump may experience problems such as a loss of capacity, cavitation or gas locking. This applies, for example, when pumping sodium hypochlorite, where gas formation must be taken into account right from the system design stage.

When particles cause abrasion, the pump’s wear mechanisms also need to be analysed. Read more about this in the article ‘Wear in pump systems’.

Flow rate, back pressure and suction head

Flow rate and pressure are fundamental design parameters. The pump must be capable of delivering the required flow rate at the back pressure present in the system.

The suction head is also a factor. An installation where the pump needs to lift liquid from a lower level has different requirements to one where the liquid flows to the pump’s inlet. If the suction head is high or if the system needs to be able to empty a tank, a self-priming pump may be appropriate.

For seal-less centrifugal pumps, for example, Lymas’s range includes self-priming models. However, the most suitable solution depends on the fluid and the specific installation.

Continuous or intermittent operation

How the pump is used also influences the choice. A pump that is to operate continuously for long periods must be selected taking into account the load, cooling and service life.

In intermittent operation, other factors may become more important, such as the number of starts and stops, and how quickly the pump needs to reach the required capacity.

Dry running is another important issue. Some types of pump are more susceptible to dry running than others. Lymas’ diaphragm pumps, for example, are dry-running-proof and may be a suitable option in applications where there is a risk of the pump temporarily running without fluid.

Which pump is suitable for hydrochloric acid?

For hydrochloric acid, a seal-less, magnetically driven centrifugal pump with chemically resistant materials in the wetted parts is often a suitable option. Under other conditions, such as where self-priming is required or there is a risk of dry running, a diaphragm pump may be a better choice.

Fact box – Pump for hydrochloric acid

Recommended pump type: Seal-less, magnetically driven centrifugal pump

Options: Pneumatic diaphragm pump for special operating conditions

Recommendations and materials for wet areas

When pumping hydrochloric acid, seal-less magnetically driven centrifugal pumps can be a good option for ensuring a steady flow and leak-free transport.

For applications where particles, self-priming, dry running or other process conditions make a centrifugal pump less suitable, a compressed-air-driven diaphragm pump may be an alternative. Diaphragm pumps are available in various materials and are designed for use with, amongst other things, aggressive chemicals.

The material used in the wet parts must always be checked against the current hydrochloric acid concentration and temperature. Material compatibility tables show, for example, that PVDF and PTFE may be suitable for many hydrochloric acid applications, whilst stainless steel should not be regarded as a general option.

Please feel free to read more about seal-less centrifugal pumps and compressed-air-driven diaphragm pumps.

When the recommendation changes

The recommendation may change when the concentration, temperature, flow rate or pressure changes. A material that is suitable at a particular temperature may have a lower chemical or mechanical safety margin at higher temperatures.

Examples from a completed installation

Medium: hydrochloric acid

Concentration: [to be confirmed]

Temperature: [to be confirmed]

Flow: [to be confirmed]

Press: [confirm]

Pump type: [to be confirmed]

Materials used in wet areas: [to be confirmed]

Pump model: [to be confirmed]

Which pump is suitable for sodium hypochlorite?

For sodium hypochlorite, a chemical-resistant pump with PVDF, PTFE or another verified material in the parts in contact with the fluid is often appropriate, and the choice of pump type must take particular account of gas formation in the medium. For dosing, a diaphragm or dosing pump may be suitable, whilst other flow requirements may call for a centrifugal pump.

A pump for sodium hypochlorite must therefore be selected taking into account both chemical compatibility and the risk of gas formation. It is not enough simply to check whether the pump casing itself can withstand the medium.

Gas formation and what it requires

Sodium hypochlorite can release gas over time. This gas formation is important because gas in the liquid side of the pump can affect the pump’s operation and make it more difficult to maintain a stable flow.

In the case of a chlorine pump, therefore, both the pump and the system must be sized taking into account the properties of the fluid. The suction, pipework and positioning of the pump can be of great importance.

In dosing applications, a pump design that copes better with gas formation may be necessary. Degassing solutions may also be appropriate, depending on the system’s design.

Recommendations and materials for wet areas

For sodium hypochlorite, PVDF and PTFE are materials that are frequently used where high chemical resistance is required. However, the choice of material must always be checked against the actual concentration and temperature.

A diaphragm pump may be a suitable option for dosing sodium hypochlorite.

When the recommendation changes

Concentration and temperature are particularly important when dealing with sodium hypochlorite. Materials that perform well at a certain concentration and temperature may be unsuitable under other conditions.

Metals that are not sufficiently resistant to chloride-containing and oxidising media may be subject to corrosion. Stainless steel should therefore not be chosen as a matter of course for sodium hypochlorite.

Elastomers and seals must also be checked. A choice of material that is suitable for the pump casing itself does not automatically mean that all other components in contact with the fluid are compatible.

Which pump is suitable for sodium hydroxide solution?

For caustic soda, i.e. sodium hydroxide solution, the choice of pump depends primarily on concentration, temperature, flow rate and pressure. A diaphragm pump may be an option for chemical transfer or dosing, whilst centrifugal pumps may be suitable for larger and steady flow rates once the choice of material has been verified.

When pumping sodium hydroxide solution, the choice of material is particularly important, as sodium hydroxide can affect different materials in different ways. PTFE offers broad chemical resistance, whilst other materials need to be assessed on the basis of the specific concentration and temperature.

Seals and other components that come into contact with fluids must also be included in the material assessment. Therefore, a chemical pump should not be specified solely on the basis of the pump’s main material.

Common mistakes and what they cost

Choosing the wrong pump is not always down to the pump type itself being incorrect. Often, the problem lies in the choice of materials, the sizing, or the fact that one of the process parameters has been overlooked.

Wrong choice Consequence What should have been chosen?
Stainless steel is selected without checking the chloride content of the medium Corrosion, pitting and reduced service life Material verified for the relevant medium
The pump is sized solely on the basis of the required flow rate Insufficient capacity at the current back pressure Sizing based on flow, pressure and system curve
Gas formation in the medium is overlooked Unstable operation, capacity issues or gas lock-up Pump type and installation designed to cope with gas formation
Particles in the medium are overlooked Abrasion and premature wear Pump with a design and materials suitable for particles
Seals are selected without checking for chemical compatibility Swelling, leakage or material failure Inspection of all materials in contact with liquids

How we draw up a recommendation

In order to recommend the right pump, we need to understand the application in its entirety. The more comprehensive the information provided, the easier it is to assess the pump type, materials and sizing.

When we draw up a recommendation, the following information is particularly important:

  • Medium – the exact chemical and any mixture.
  • Concentration – for example, percentage content.
  • temperature – normal temperature and any temperature peaks.
  • Flow – desired or necessary flow.
  • Pressure and suction head – back pressure, differences in level and any self-priming requirements.
  • Particles and viscosity – if the medium contains solid particles or differs from water in terms of viscosity.
  • Operating conditions – continuous or intermittent operation, starts and stops, and any risk of running dry.

Based on this information, the pump’s capacity, design and materials can be assessed as a whole. Lymas’s range of pumps includes, amongst others, centrifugal pumps, diaphragm pumps, peristaltic pumps and dosing pumps for various types of process applications.

Please feel free to all our pumps or use the ‘Search for your pump here’ service:

Questions and Answers – Frequently Asked Questions about selecting pumps for corrosive media

Which pump is best suited for hydrochloric acid?

This depends on concentration, temperature, flow rate and pressure. A seal-less centrifugal pump may be suitable in many cases, whilst a diaphragm pump may be an alternative. The material must always be selected to suit the medium.

Which pump is suitable for sodium hypochlorite?

A chemical-resistant diaphragm pump or centrifugal pump may be suitable. However, the choice of pump is influenced by factors such as gas formation, concentration and temperature.

Which pump is suitable for sodium hydroxide solution?

Both diaphragm pumps and centrifugal pumps can be used, depending on the flow rate, pressure, concentration and temperature.

Which material can withstand aggressive chemicals?

It depends on the medium to be pumped. Materials such as PVDF, PTFE and PP may be suitable for various chemicals, but must always be checked against the specific concentration and temperature.

How does concentration affect the choice of pump?

Higher concentrations may place greater demands on the chemical resistance of the materials and may therefore influence both the type of pump and the choice of materials.

What information is needed to choose the right pump?

The medium, concentration, temperature, flow rate, pressure, suction head, particles, viscosity and operating conditions are important factors to consider when selecting a pump.

Do you need help choosing the right pump?

At Lyma, we have extensive experience of working with corrosive and abrasive fluids, and can assist with assessing the pump type, materials and sizing.

Does your business need a chlorine pump, a chemical dosing pump or another solution for corrosive media? Contact us for help finding the right pump!